What cable gauge avoids voltage drop?

Work out the voltage drop and the minimum cable cross-section for your solar or 12V setup: current, length, gauge, an instant verdict.

Work out the voltage drop and the minimum cable cross-section for your solar or 12V setup: current, length, gauge, an instant verdict.

What cable gauge?
The right wire gauge for your solar or 12 V setup, and what an undersized cable really costs you.

⚡ Your circuit

A cable that's too thin over a long run drops the voltage before it even reaches the battery: less charging current, and sometimes a controller that cuts out. Pick a panel from our catalogue or enter your own values.

Voltage drop
0.9 %
ideal
Voltage drop
-0.46 V
Voltage at the far end
47.54 V
Recommended minimum gauge
14 AWG

Direct-current calculation, cable there-and-back, copper resistivity at operating temperature (0.0225 Ω·mm²/m at 70 °C, converted here to standard AWG cross-sections). By default, picking a panel sets the current to its Isc (short-circuit current), the most conservative sizing value. As a rule of thumb, keep drop at or under 3% on a branch circuit, matching the widely used NEC voltage-drop recommendation.

→ See our solar cables and extensions

Voltage drop by wire gauge, for this current and length

Gauge Drop Voltage at end Verdict
14 AWG2.4 %46.85 Videal
12 AWG1.5 %47.28 Videal
10 AWG0.9 %47.54 Videal
8 AWG0.6 %47.71 Videal
6 AWG0.4 %47.82 Videal
4 AWG0.2 %47.89 Videal
2 AWG0.1 %47.93 Videal
1 AWG0.1 %47.94 Videal
1/0 AWG0.1 %47.96 Videal