Bluetti Apex 300: our full review

A 2,765Wh base unit that holds its 3,840W until the battery is empty and grows to 58kWh, but whose 3,840W charging and USB and 12V outputs all come as paid accessories.

Our rating
4.2/5
Capacity and efficiency: 4.2 out of 5 (weighting 25%)Capacity4.2Delivered power: 4.2 out of 5 (weighting 25%)Power4.2Recharging: 4.1 out of 5 (weighting 15%)Recharging4.1Ports and control: 4.0 out of 5 (weighting 15%)Ports4.0Build and endurance: 4.3 out of 5 (weighting 12%)Build4.3

How is this rating calculated?

Bluetti Apex 300 portable power station seen from the front, screen lit, four AC outlets under rubber covers and the 3840W 2764.8Wh marking

The essentials

The Apex 300 delivers most of what it promises: 3,840W held until the battery is empty, a standby draw of around 20W and 83 to 93% of its capacity delivered depending on the load. Its limits lie elsewhere. The 45 minutes to reach 80% need 3,840W of input, so an optional 30A or 50A cable into the P050A port, while the standard 15A cord tops out at 1,800W. It has no USB or 12V outlet without the Hub D1, weighs 84 lb (38 kg) with no wheels, and its solar inputs stay in practice below 1,200W each. For home backup that grows in steps, it is one of the most coherent bases in its category; for portable use, an Elite is simpler.

Strengths

  • 3,840W held until the battery is empty, with 92% efficiency at that load
  • Standby draw limited to around 20W, inverter on and nothing plugged in
  • Expansion to 19.4kWh per unit with six B300K (or 5,120Wh B500K), and 58kWh with three units linked by the Hub A1
  • Full recharge in about 2 hours from a standard outlet, up to 3,840W with the optional cable on the P050A port
  • Six outlets (four 20A, one TT-30R, one 14-50R) with a 120/240V selector, and a 20ms UPS changeover (0ms in a 240V setup)
  • LiFePO4 cells rated for 6,000 cycles to 80% and a five-year manufacturer warranty on the unit

Limitations

  • No USB, 12V or Anderson output without the Hub D1, sold for $299 on top
  • The claimed 45 minutes to 80% need 3,840W of input: the standard 15A cord tops out at 1,800W, and the fast path needs an optional 30A or 50A cable
  • Solar input rated at 2 x 1,200W, but bounded to 60V and 20A: the 1,200W per connector stays theoretical
  • 84 lb (38 kg) with no wheels and an IP20 rating: a fixed, sheltered installation rather than a portable unit
  • About 76% of the energy recovered over a full cycle, and a Silent mode down to nearly 50% efficiency over the first third of a charge
  • Power Lifting is limited to purely resistive loads, with a real power below the appliance's rated value
Cost of available energy
614 $per kWh returned

Computed from today's price and the measured capacity, not the claimed capacity. Cheaper than 4 of the 16 comparable products in the catalogue, on claimed capacity.

Bluetti Apex 300: see the full details and price →

What the rated 2,764.8Wh is really worth

Bluetti rates the Apex 300 at 2,764.8Wh (LiFePO4 cells, 51.2V and 54Ah). What reaches the outlets depends on the power drawn: on the 120V US version, a full discharge under a dehumidifier load delivers 2,290Wh, while the 230V version sold in Europe delivers 2,580Wh at 2,000W, or 83 to 93% of the nominal figure. In between, a full discharge into a resistive load delivers about 2,440Wh (88%), and a discharge at 3.8kW about 2,550Wh (92%).

2,440 Wh
delivered into a resistive load (230V)
88 %
of nominal into a resistive load
93 %
of nominal at 2kW (230V)

The gap has a simple cause: the inverter and the electronics use around 20W all the time, whatever is plugged in. At 2,000W, those 20W are 1% of the energy delivered; at 150W, more than 10%. The manufacturer builds this into its own runtime formula: capacity, multiplied by 95% depth of discharge and by an inverter efficiency above 90%, divided by the load plus 20W.

Rated capacity of 2,764.8Wh compared with the energy actually delivered under different loadsRated capacity2,765Wh2kW, 230V2,580Wh (93%)3.8kW, 230V2,550Wh (92%)Resistive, 230V2,440Wh (88%)Dehumidifier, 120V2,290Wh (83%)
Energy actually delivered at the outlets depending on the load applied (different loads and regional versions from one bar to the next).

In home backup, most loads (fridge, router, lighting, computer) stay under 300W, so you land towards the bottom of the range, around 2,300 to 2,450Wh of usable energy. A space heater or a kettle sits nearer the top. Set against the energy that is really available, the $1,499 base unit works out at about $615 per kWh delivered, against $542 per nominal kWh.

The 20W standby draw and round-trip efficiency

With the unit on, the inverter active and nothing plugged in, its own consumption is around 20W. That is 480Wh a day, or 17% of the capacity, and about 14kWh a month. A full battery runs flat in about five and a half days without powering anything (2,626Wh usable at 95% depth of discharge, divided by 20W).

20 W
own consumption with no load
480 Wh
lost every day on standby
76 %
of the energy recovered over a full cycle

ECO mode limits this drift. On by default, it switches the AC output off after 4 hours below 10W of load. The manufacturer nonetheless advises switching it off for devices under 60W and for loads that must never be interrupted, such as lighting or a fridge.

A full cycle is less efficient than a discharge on its own. On the 230V version, filling the battery from empty takes 3.35kWh from the grid in Turbo mode (3.39kWh in Standard), and the discharge delivers 2.58kWh at best: about 76% of the energy drawn, because that figure includes the charger, the battery management and the 5% of capacity the unit never empties.

Energy drawn from the grid for a full recharge compared with the energy delivered at 2kWGrid, Standard mode3,390WhGrid, Turbo mode3,350WhRated capacity2,765WhDelivered at 2kW2,580Wh
Energy balance of a full cycle on the 230V version: about 76% of the energy drawn from the grid is delivered back.

The Silent charging mode is not the most economical. It starts at around 500W, drops to 200W at about 20% charge and, over the first third of the battery, more than 1.7kWh is drawn from the grid, an efficiency close to 50%. For a charge quieter than Turbo, Standard mode gives a much better balance.

With time-of-use scheduling or self-consumption, these losses add up: about a quarter of the stored energy disappears over the cycle, and 480Wh a day comes on top if the unit stays on. The financial case for rate arbitrage has to be worked out with both losses, not just the price per kWh.

3,840W held, 7,680W with conditions

The unit is rated for 3,840W continuous, shared across four NEMA 5-20R outlets (20A each in 120V mode), a TT-30R and a 14-50R; in 240V mode, the 14-50R delivers the full 3,840W at 16A. It holds that figure: discharging at 3.8kW on the 230V version, it delivers 2,550Wh before stopping, at 92% efficiency, with no cut-out or throttling along the way. Two fan heaters of 1.8kW and 2kW plugged in together (3.3kW) pass without difficulty, and neither a kettle, a vacuum cleaner nor an electric stove top has managed to trip it.

The 7,680W figure comes from Power Lifting mode, which is off by default. It only applies to purely resistive loads (kettle, space heater, hair dryer) rated between 3,840 and 7,680W, and the manual states that the power the appliance actually draws stays below its rated value: the unit lowers the voltage to stay within its limits rather than supplying more energy. In one specific case, a 4.3kW load held for the whole boil of a kettle, while a 4.8kW load cut the output within 7 seconds.

What the unit holds in practice depending on the load applied (230V version)
Load appliedPowerResult
Full discharge at full power3.8kW2,550Wh delivered, no cut-out before the battery ran flat
Two fan heaters (1.8kW and 2kW)3.3kWHeld without difficulty
Power Lifting: heater, air fryer and kettle4.3kWHeld for the whole boil
Power Lifting: two heaters and a kettle4.8kWOutput cut after 7 seconds
Claimed peak, purely resistive loads7,680WA ceiling setting: the appliance's real power stays below its rated value

For a motor or a compressor (pump, air conditioner, power tool), Power Lifting does not apply: the manual warns that such devices can start at 2 to 4 times their rated power and overload the inverter, without quoting any surge above 3,840W. By way of example, a 1,500W motor that starts at three times its rated power draws 4,500W, beyond what the unit accepts.

In parallel, two units linked by the Hub A1 raise the power to 7,680W (the output is set to 240V by default in that mode), three to 11,520W. Plugged into a standard outlet, the unit takes from the wall what its input allows, 1,800W at most, and draws the rest from the battery: at a 3,840W load, about 2,000W is missing.

Charging and solar: the claimed 45 minutes come with a condition

The manufacturer claims 80% in 45 minutes. That is correct, but only with 3,840W of input, which the standard wall cord cannot supply: its input is limited to 1,800W (15A at 120V), and the default grid current of 12A gives the 1,440W of Standard mode. On the 230V version, the three modes on the front panel give 508W in Silent, 1,442W in Standard and 2,330W in Turbo at peak, in line with the manufacturer's ceilings of 500, 1,440 and 2,300W.

1,800 W
ceiling of the standard wall cord (120V)
2 h
for a full recharge in Standard mode
45 min
to 80% with 3,840W of input
Apex 300 charging by route used (US version)
Charging routeMaximum powerTime
Silent mode, standard 15A cord500WMore than 5.5 hours at best, far longer in practice
Standard mode, standard 15A cord1,440WAbout 2 hours for a full charge
Turbo mode, standard 15A cord1,800WA small gain over Standard mode
Turbo mode via the P050A port with an optional TT-30P or L14-50P cable3,840W80% in about 45 minutes between 59 and 77 °F (15 and 25 °C)
Grid and solar combined3,840WCombined ceiling (6,240W with one or more B300K)
Cigarette lighter (cable supplied)96W at 12V, 192W at 24VNearly 29 hours at 12V

The fast path goes through the P050A port with an optional TT-30P or L14-50P cable, and calls for a dedicated circuit: the manual suggests a 2-pole 60A overcurrent protection device upstream and advises consulting a licensed electrician. The Hub A1 package costs $699 for two units. Without it, the simplest way past 1,800W is to combine the grid and solar, within the 3,840W limit.

On the solar side, two XT60 inputs each accept 12 to 60V and 20A, or 1,200W nominal per input and 2,400W in total. That ceiling stays theoretical: 1,200W would need a panel string at 60V at its maximum power point, whereas 60V is the maximum open-circuit voltage, and a string typically works at around 80% of its open-circuit voltage, which brings 20A down to about 1,000W per input. Below 30V, the current is also limited to 8.2A in the app's standard setting; the advanced mode keeps that limit only below 16V.

To make use of a roof array, the SolarX 4K controller ($699) accepts up to 4,000W, on top of the XT60 inputs.

No USB or 12V outlet: the Hub D1 becomes mandatory

The front panel offers four NEMA 5-20R outlets, a TT-30R for RV plugs and a 14-50R, with a 120V/240V selector: pushing it up gives 120V, down gives 240V, and switching between the two cuts the AC output. No USB, no 12V, no Anderson: those outputs go through the Hub D1, a $299 box that plugs into the expansion port. It adds two 100W USB-C ports, two USB-A ports, two cigarette-lighter sockets, two DC5521 sockets and a 50A Anderson connector (12V at 50A or 24V at 25A), within a combined limit of 700W: beyond that, the hub goes into protection.

For home backup (fridge, router, computer), the AC outlets are enough. For an RV or a van, the Hub D1 is essential: without it, the unit cannot feed the on-board 12V equipment.

The AC outlets are controlled as a block: the AC button on the front and the app switch the whole AC output on or off. The app (Bluetooth and Wi-Fi) shows the state of the inputs and outputs, the UPS, time-of-use and self-consumption modes, and the firmware updates, which the manual recommends installing before first use. Power Lifting, ECO mode and the child lock are set from the unit's settings mode or the app. Once switched off, the unit cannot be switched back on remotely.

Modularity: the real bill for a system

Expansion is the central argument. The manual allows up to six B300K batteries of 2,764.8Wh per unit, or 19.4kWh in total with the unit itself, and the manufacturer also sells 5,120Wh B500K batteries. With the Hub A1, two units and twelve B300K give 7,680W and 38.7kWh, three units and eighteen B300K give 11,520W and 58kWh; with B500K batteries, the quoted ceiling approaches 100kWh.

List prices of the parts of an Apex 300 system (manufacturer's US shop, before sales tax)
ItemRolePricePrice per nominal kWh
Apex 300 (2,764.8Wh)Base unit, six AC outlets$1,499$542
B300K battery (2,764.8Wh)2,764.8Wh expansion, about 65 lb (29.5 kg)$1,199$434
B500K battery (5,120Wh)5,120Wh expansion$1,999$390
Hub D1USB, 12V and Anderson outputs$299-
Hub A1 (package for two units)Paralleling and 3,840W charging$699-
SolarX 4KSolar controller up to 4,000W$699-
Foldable trolleyWheels for the unit and its batteries$249-

On the price per nominal kWh, expansion beats the base unit: $542 per kWh for the unit, $434 for a B300K and $390 for a B500K. An 8.3kWh system with solar (unit, two B300K, Hub D1 and SolarX 4K) therefore reaches $4,895 at list price, more than three times the entry price.

A few assembly rules: all units must be switched off before a battery is connected, the manual recommends wall-mounting stacks of two or more B300K with metal brackets, and advises against mixing B300 and B300S batteries. Each B300K weighs about 65 lb (29.5 kg): a unit with three B300K exceeds 275 lb (125 kg).

UPS, backup and wiring: what the manual allows

Plugged into the grid, the unit powers devices directly and switches to battery within 20ms when the supply drops, provided they are connected to the outlets intended for UPS mode (set in the app). For a seamless 0ms changeover, the manual asks for the 240V setting, the 15A AC input and essential loads on the two left outlets. That is short enough for a router, a modem or a desktop computer; it is not a UPS for servers or workstations that need high-performance protection, which the manual expressly rules out.

When the battery has run flat, the unit remembers the state of its outputs and restores them automatically when the grid returns. If the charge falls to 0%, the unit must be switched off and charged for at least 30 minutes before being restarted.

Minimum runtime by constant load (calculation from the manufacturer's formula)
Constant loadMinimum runtime
40W39.4 hours
100W19.7 hours
250W8.8 hours
300W7.4 hours
2,000W1.2 hours
3,840W0.6 hours, or 37 minutes

These runtimes are floors: they assume 90% inverter efficiency, 95% depth of discharge and the 20W standby draw. The 2,550 to 2,580Wh delivered under heavy load exceed that floor by 8 to 10%.

Wiring the unit into the house for automatic backup goes through the P050A port, the Hub A1 and upstream protection. That job belongs to a licensed electrician: it is not a plug-in connection, and extension cords remain the simplest way to back up a few appliances.

Three versions, not one product: 120/240V, 230V and 13A

The Apex 300 comes in market-specific versions, with separate references for the United States, Europe and the United Kingdom. Delivered-capacity figures carry over from one version to another; power and charging figures do not. Each column below applies to its own version, and the US one is the version sold here.

The three versions of the Apex 300: outlets, charging and UPS
FeatureEurope (230V)United Kingdom (230V)United States (120/240V)
Front outlets4 sockets of 16A4 sockets of 13A4 NEMA 5-20R outlets (20A), one TT-30R and one 14-50R
Voltage selectorNoNoYes, 120V or 240V
Standard wall input2,300W (10A)2,300W (10A)1,800W at most (15A, 120V)
3,840W chargingHub A1 on the P050A inputHub A1 on the P050A inputOptional TT-30P or L14-50P cable to the P050A
UPS changeover20ms20ms0ms or 20ms depending on the setup

The US version, with its six outlets and 120/240V selector, answers uses the other two do not (RV, electric range, well pump, vehicle charging). The weight (84 lb, 38 kg), the dimensions (20.7 x 12.9 x 12.6 in, 52.5 x 32.7 x 32 cm), the 2,764.8Wh capacity and the IP20 rating are the same from one version to the next.

Weight, build quality and warranty

At 84 lb (38 kg), with two side handles and no wheels (a folding trolley is sold as an option), the Apex 300 is put down once. Its IP20 rating limits it to a dry, sheltered room. It discharges from -4 °F (-20 °C) to 104 °F (40 °C) but only recharges between 32 °F (0 °C) and 104 °F (40 °C): an unheated garage in winter can therefore interrupt charging. If it has dropped to 0%, the manual asks you to keep it between 41 °F (5 °C) and 95 °F (35 °C) for 6 hours before recharging.

Bluetti quotes automotive-grade LiFePO4 cells and 6,000 cycles to 80% of capacity. The construction is dense: rubber covers on the outlets, a removable dust filter, active cooling. No safety recall specific to the Apex 300 has been found to date, on a product on sale for less than fifteen months: the track record is still short.

The fans are audible during Turbo charging and under heavy load, and the top of the unit warms up during fast charging; Silent mode limits charging to about 500W to stay discreet. No decibel figure is published with a usable protocol: the noise axis is therefore not scored.

The manufacturer's warranty table gives the unit 60 months, the B300K expansion batteries 48 months and accessories 12 months: the five years apply to the base unit only, and the Hub D1 and the other add-ons are covered for a shorter time. The warranty requires proof of purchase from an authorized seller and excludes unauthorized modifications or repairs.

For long-term storage: charge to between 40 and 60%, switch off, unplug all cables, store between 14 °F (-10 °C) and 104 °F (40 °C) (below 95 °F (35 °C) beyond a month) and run a full cycle every three months. The manual recommends recharging from the grid, or from solar with at least 100W of input.

Against the Elite 400, Delta Pro 3 and SOLIX F3800

For $100 less ($1,399), the Elite 400 offers 3,840Wh, built-in USB and 12V outputs and wheels, but only 2,600W shared across its outlets and no expansion. The Apex 300 turns the equation around: less energy to start with (2,765Wh), more power (3,840W), six outlets with a 240V option, expansion up to 19.4kWh and 6,000 rated cycles against 3,000.

Bluetti Apex 300 against its main alternatives
CriterionBluetti Apex 300Bluetti Elite 400EcoFlow Delta Pro 3Anker SOLIX F3800
Base capacity2,765Wh3,840Wh4,096Wh3,840Wh
Continuous power3,840W2,600W4,000W6,000W
Maximum expansion (one unit)19.4kWhNot expandable12.3kWh26.9kWh
Built-in USB-CNone (Hub D1)2 x 100W2 x 100W3 x 100W
WheelsNoYesYesYes
Weight84 lb (38 kg)86 lb (39 kg)113.5 lb (51.5 kg)132 lb (60 kg)
UPS changeover20ms15ms10ms30ms
Rated cycles to 80%6,0003,0004,0003,000
Indicative list price$1,499$1,399$2,799$2,000

The Delta Pro 3 (4,096Wh, 4,000W, expandable to 12.3kWh) has all its outputs built in, switches over in 10ms and shows a higher discharge efficiency, but costs almost double ($2,799) and weighs 113.5 lb (51.5 kg) against 84 lb (38 kg). The SOLIX F3800 (3,840Wh, 6,000W, expandable to 26.9kWh) beats it on power and on expansion for about $500 more, at the cost of 132 lb (60 kg).

On expansion, the Apex 300 sits between the two: 19.4kWh per unit, against 12.3kWh for the Delta Pro 3 and 26.9kWh for the SOLIX F3800. Its own argument is a lower entry price than either rival's for 3,840W and 6,000 rated cycles, with the drawback of a system that needs accessories to be complete.

Who is the Apex 300 really for?

The Apex 300 is aimed first at home backup that grows in steps: six outlets, 3,840W, a 120/240V selector, a 20ms changeover and the option to add capacity when the budget allows. It also suits an off-grid cabin or a second home fed by solar panels, provided you plan for the SolarX 4K to make use of a roof array, and an RV or converted van where it stays installed permanently, with the Hub D1 and an alternator charger.

It is a poor fit for anyone who wants to move it often (84 lb, no wheels), who counts on the 45-minute recharge without the optional cable and a dedicated circuit, who wants USB and 12V outputs without an accessory, or who has to protect servers or a critical workstation, for which the manufacturer advises against the unit.

At $1,499, the base unit stays accessible for 3,840W of power; the real bill depends on the modules, the hub and the solar. Before buying: list the appliances to back up and what they draw, choose between extension cords and a connection to the electrical panel, and price the complete system rather than the unit alone.

The rating in detail

Our rating
4.2/5
Capacity and efficiency 4.2
Delivered power 4.2
Recharging 4.1
Ports and control 4.0
Build and endurance 4.3
Noise not measured
Bluetti Apex 300: see the full details and price →

The product and its alternatives

Bluetti Apex 300

Bluetti Apex 300

$1499.00 (9)

Bluetti's modular home battery backup: a 3840 W core, batteries added as your needs grow, and a UPS that switches over to battery in just 20 ms.

View product
EcoFlow Delta Pro 3

EcoFlow Delta Pro 3

See price (4)

4096Wh and 4000W output to power a whole home, quiet (30 dB) and expandable up to 12 kWh: the home backup station par excellence.

View product
Anker SOLIX F3800

Anker SOLIX F3800

See price (11)

3840Wh, true 120V/240V split-phase 6000W output through NEMA 14-50 and L14-30 outlets, expandable to 26.9kWh: the Anker station built to back up a whole home.

View product
Bluetti Elite 400

Bluetti Elite 400

$1399.00 (2)

3840Wh and 2600W (3900W Power Lifting) in a rolling power station: 80% recharge in 1h, 15ms UPS switching and remote Wi-Fi control.

View product

Need help choosing?

Frequently asked questions

To 80% of its capacity, yes, but only with 3,840W of input, meaning an optional TT-30P or L14-50P cable into the P050A port on a dedicated circuit. From a standard 120V wall outlet, charging tops out at 1,800W: about 2 hours for a full charge.

Between 2,290 and 2,580Wh out of 2,764.8Wh, or 83 to 93% depending on the load: 2,290Wh under a dehumidifier load on the 120V version, about 2,440Wh into a resistive load (88%), 2,550Wh at 3.8kW and 2,580Wh at 2kW on the 230V version. The gap comes from the unit's own consumption of around 20W.

No. Only the AC outlets are built in. The 100W USB-C ports, USB-A ports, cigarette-lighter sockets and the 50A Anderson connector go through the Hub D1, sold for $299, within a combined 700W limit.

Yes, with a 20ms changeover on the outlets intended for UPS mode (0ms in a 240V setup with the 15A AC input), enough for a router, a modem or a desktop computer. The manufacturer advises against it for servers and workstations that need a high-performance UPS.

Up to six batteries per unit: six B300K (19.4kWh in all) or six 5,120Wh B500K. Three units can be linked by the Hub A1: 11,520W and 58kWh with B300K, about 100kWh with B500K.

About 20W with the unit on and no load, or 480Wh a day (17% of the capacity). ECO mode, on by default, switches the AC output off after 4 hours below 10W.